Ticket #61 (closed defect: fixed)

Opened 5 years ago

Last modified 5 years ago

Measurements with decimals are not stored in subject layout

Reported by: janneke@… Owned by: janneke@…
Priority: critical Milestone:
Component: Assay importer Version:
Keywords: Cc:
Hardware: Operating system:
Product: URL:

Description

Importing assay using subject layout, results in only a few measurements: Only measurements without decimals are saved.

Use following data to reproduce (and store under new subassay, and use study pps2_31)

mouse #	0	4	8	12
200	25,7	28,2	29,1	30,3
201	25,3	27,9	28,7	29,1
202	26,4	28,8	30,5	28,5
203	24,4	26	27,1	26,6
204	24,2	26,6	27,5	28
205	24,4	25,7	26,4	27,1
206	22,9	24,9	25,6	25

Change History

comment:1 Changed 5 years ago by taco@…

  • Status changed from new to assigned
  • Owner changed from taco@… to janneke@…

This problem should be resolved now.

Revision [235].

comment:2 Changed 5 years ago by janneke@…

  • Status changed from assigned to closed
  • Resolution set to fixed
Note: See TracTickets for help on using tickets.